One Hat Cyber Team
Your IP :
216.73.216.42
Server IP :
203.175.9.166
Server :
Linux tanggamus.iixcp.rumahweb.net 5.14.0-427.28.1.el9_4.x86_64 #1 SMP PREEMPT_DYNAMIC Fri Aug 2 03:44:10 EDT 2024 x86_64
Server Software :
LiteSpeed
PHP Version :
7.4.33
Buat File
|
Buat Folder
Eksekusi
Dir :
~
/
lib
/
netdata
/
conf.d
/
go.d
/
snmp.profiles
/
default
/
View File Name :
hpe-proliant.yaml
extends: - _hp.yaml - _hp-base.yaml - _hp-compaq-health.yaml - _hp-driver-stats.yaml - _std-if-mib.yaml - _std-tcp-mib.yaml - _std-udp-mib.yaml - _std-ip-mib.yaml selector: - sysobjectid: include: - 1.3.6.1.4.1.232.* metadata: device: fields: product_name: value: ProLiant vendor: value: hp model: symbols: - MIB: CPQSINFO-MIB OID: 1.3.6.1.4.1.232.2.2.4.2 name: cpqSiProductName extract_value: '\s*ProLiant\s*([-a-zA-Z0-9_ ]+)' # The product name. e.g. ProLiant BL35p G1, only extract "BL35p G1" - MIB: CPQSINFO-MIB OID: 1.3.6.1.4.1.232.2.2.4.2 name: cpqSiProductName # Fallback if unable to parse the product name # - CPQSTDEQ-MIB # https://mibbrowser.online/mibdb_search.php?mib=CPQSTDEQ-MIB # https://github.com/DanielleHuisman/observium-community-edition/blob/main/mibs/hp/CPQSTDEQ-MIB # - CPQHOST-MIB # https://mibbrowser.online/mibdb_search.php?mib=CPQHOST-MIB # https://github.com/DanielleHuisman/observium-community-edition/blob/main/mibs/hp/CPQHOST-MIB # - CPQSINFO-MIB # https://mibbrowser.online/mibdb_search.php?mib=CPQSINFO-MIB # https://github.com/DanielleHuisman/observium-community-edition/blob/main/mibs/hp/CPQSINFO-MIB # - CPQNIC-MIB # https://mibbrowser.online/mibdb_search.php?mib=CPQNIC-MIB # https://github.com/DanielleHuisman/observium-community-edition/blob/main/mibs/hp/CPQNIC-MIB # - CPQIDA-MIB # https://mibbrowser.online/mibdb_search.php?mib=CPQIDA-MIB # https://github.com/DanielleHuisman/observium-community-edition/blob/main/mibs/hp/CPQIDA-MIB metrics: - MIB: CPQSTDEQ-MIB table: OID: 1.3.6.1.4.1.232.1.2.2.1 name: cpqSeCpuTable symbols: - OID: 1.3.6.1.4.1.232.1.2.2.1.1.4 name: cpqSeCpuSpeed chart_meta: description: Current internal speed of the processor in megahertz family: 'Hardware/CPU/Speed/Internal' unit: "MHz" - OID: 1.3.6.1.4.1.232.1.2.2.1.1.6 name: cpqSeCpuStatus chart_meta: description: Status of the processor family: 'Hardware/CPU/Status' unit: "{status}" mapping: 1: unknown 2: ok 3: degraded 4: failed 5: disabled - OID: 1.3.6.1.4.1.232.1.2.2.1.1.7 name: cpqSeCpuExtSpeed chart_meta: description: External frequency of the processor bus in megahertz family: 'Hardware/CPU/Speed/External' unit: "MHz" metric_tags: - tag: cpu_index symbol: OID: 1.3.6.1.4.1.232.1.2.2.1.1.1 name: cpqSeCpuUnitIndex - tag: cpu_max_threads symbol: OID: 1.3.6.1.4.1.232.1.2.2.1.1.25 name: cpqSeCPUCoreMaxThreads - tag: cpu_cores symbol: OID: 1.3.6.1.4.1.232.1.2.2.1.1.15 name: cpqSeCpuCore - tag: cpu_primary symbol: OID: 1.3.6.1.4.1.232.1.2.2.1.1.27 name: cpqSeCpuPrimary mapping: 1: unknown 2: false 3: true - MIB: CPQHOST-MIB table: OID: 1.3.6.1.4.1.232.11.2.3.1 name: cpqHoCpuUtilTable symbols: - OID: 1.3.6.1.4.1.232.11.2.3.1.1.2 name: cpu.usage # cpqHoCpuUtilMin chart_meta: description: The current CPU utilization family: 'System/CPU/Usage' unit: "%" metric_tags: - tag: cpu_unit_index symbol: OID: 1.3.6.1.4.1.232.11.2.3.1.1.1 name: cpqHoCpuUtilUnitIndex - MIB: CPQHOST-MIB table: OID: 1.3.6.1.4.1.232.11.2.4.1 name: cpqHoFileSysTable symbols: - OID: 1.3.6.1.4.1.232.11.2.4.1.1.3 name: cpqHoFileSysSpaceTotal scale_factor: 1048576 chart_meta: description: File system size family: 'System/FileSystem/Size' unit: "By" - OID: 1.3.6.1.4.1.232.11.2.4.1.1.4 name: cpqHoFileSysSpaceUsed scale_factor: 1048576 chart_meta: description: Megabytes of file system space currently in use family: 'System/FileSystem/Used' unit: "By" - OID: 1.3.6.1.4.1.232.11.2.4.1.1.5 name: cpqHoFileSysPercentSpaceUsed chart_meta: description: Percent of file system space currently in use family: 'System/FileSystem/Usage' unit: "%" - OID: 1.3.6.1.4.1.232.11.2.4.1.1.6 name: cpqHoFileSysAllocUnitsTotal chart_meta: description: Total number of files that can be stored on the file system if a limit exists family: 'System/FileSystem/Files/Maximum' unit: "{file}" - OID: 1.3.6.1.4.1.232.11.2.4.1.1.7 name: cpqHoFileSysAllocUnitsUsed chart_meta: description: Number of files on the file system family: 'System/FileSystem/Files/Used' unit: "{file}" - OID: 1.3.6.1.4.1.232.11.2.4.1.1.8 name: cpqHoFileSysStatus chart_meta: description: Threshold status of the file system family: 'System/FileSystem/Status' unit: "{status}" mapping: 1: unknown 2: ok 3: degraded 4: failed metric_tags: - tag: file_sys_index symbol: OID: 1.3.6.1.4.1.232.11.2.4.1.1.1 name: cpqHoFileSysIndex - tag: file_sys_descr symbol: OID: 1.3.6.1.4.1.232.11.2.4.1.1.2 name: cpqHoFileSysDesc - MIB: CPQSINFO-MIB table: OID: 1.3.6.1.4.1.232.2.2.4.5 name: cpqSiMemModuleTable symbols: - OID: 1.3.6.1.4.1.232.2.2.4.5.1.3 name: cpqSiMemModuleSize scale_factor: 1024 chart_meta: description: Module memory size in kilobytes family: 'Hardware/Memory/Size' unit: "By" - OID: 1.3.6.1.4.1.232.2.2.4.5.1.5 name: cpqSiMemModuleSpeed chart_meta: description: Module memory speed in nanoseconds family: 'Hardware/Memory/Speed' unit: "ns" - OID: 1.3.6.1.4.1.232.2.2.4.5.1.11 name: cpqSiMemModuleECCStatus chart_meta: description: Current status of correctable memory errors for this memory module family: 'Hardware/Memory/ECC/Status' unit: "{status}" mapping: 1: other 2: ok 3: degraded 4: degradedModuleIndexUnknown - OID: 1.3.6.1.4.1.232.2.2.4.5.1.13 name: cpqSiMemModuleFrequency chart_meta: description: Memory module frequency in megahertz family: 'Hardware/Memory/Frequency' unit: "MHz" - OID: 1.3.6.1.4.1.232.2.2.4.5.1.15 name: cpqSiMemModuleCellStatus chart_meta: description: Current status for this memory module family: 'Hardware/Memory/Status' unit: "{status}" mapping: 1: other 2: ok 3: deconfigured metric_tags: - tag: mem_board_index symbol: OID: 1.3.6.1.4.1.232.2.2.4.5.1.1 name: cpqSiMemBoardIndex - tag: mem_module_index symbol: OID: 1.3.6.1.4.1.232.2.2.4.5.1.2 name: cpqSiMemModuleIndex - tag: mem_module_technology symbol: OID: 1.3.6.1.4.1.232.2.2.4.5.1.6 name: cpqSiMemModuleTechnology mapping: 1: other 2: fastPageMode 3: edoPageMode 4: burstEdoPageMode 5: synchronous 6: rdram - tag: mem_module_type symbol: OID: 1.3.6.1.4.1.232.2.2.4.5.1.4 name: cpqSiMemModuleType mapping: 1: other 2: board 3: cpqSingleWidthModule 4: cpqDoubleWidthModule 5: simm 6: pcmcia 7: compaq-specific 8: dimm 9: smallOutlineDimm 10: rimm 11: srimm 12: fb-dimm - MIB: CPQNIC-MIB table: OID: 1.3.6.1.4.1.232.18.2.3.1 name: cpqNicIfPhysAdapterTable symbols: - OID: 1.3.6.1.4.1.232.18.2.3.1.1.12 name: cpqNicIfPhysAdapterCondition chart_meta: description: The condition of this physical adapter family: 'Network/Interface/Condition/Status' unit: "{status}" mapping: 1: other 2: ok 3: degraded 4: failed - OID: 1.3.6.1.4.1.232.18.2.3.1.1.13 name: cpqNicIfPhysAdapterState chart_meta: description: The fault tolerant state of this adapter family: 'Network/Interface/Redundancy/Status' unit: "{status}" mapping: 1: unknown 2: active 3: standby 4: failed - OID: 1.3.6.1.4.1.232.18.2.3.1.1.14 name: cpqNicIfPhysAdapterStatus chart_meta: description: The physical adapter status family: 'Network/Interface/Link/Status' unit: "{status}" mapping: 1: unknown 2: ok 3: generalFailure 4: linkFailure - OID: 1.3.6.1.4.1.232.18.2.3.1.1.37 name: cpqNicIfPhysAdapterInOctets scale_factor: 8 chart_meta: description: Traffic received on the physical adapter family: 'Network/Interface/Traffic/Total/In' unit: "bit/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.38 name: cpqNicIfPhysAdapterOutOctets scale_factor: 8 chart_meta: description: Traffic sent on the physical adapter family: 'Network/Interface/Traffic/Total/Out' unit: "bit/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.16 name: cpqNicIfPhysAdapterGoodTransmits chart_meta: description: Successfully transmitted frames by the physical adapter family: 'Network/Interface/Frame/Transmitted' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.17 name: cpqNicIfPhysAdapterGoodReceives chart_meta: description: Successfully received frames by the physical adapter family: 'Network/Interface/Frame/Received' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.18 name: cpqNicIfPhysAdapterBadTransmits chart_meta: description: Frames that were not transmitted by the adapter because of an error family: 'Network/Interface/Frame/Error/Total/Out' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.19 name: cpqNicIfPhysAdapterBadReceives chart_meta: description: Frames that were received by the adapter but which had an error family: 'Network/Interface/Frame/Error/Total/In' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.20 name: cpqNicIfPhysAdapterAlignmentErrors chart_meta: description: Frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check family: 'Network/Interface/Error/Alignment' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.21 name: cpqNicIfPhysAdapterFCSErrors chart_meta: description: Frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check family: 'Network/Interface/Error/FCS' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.22 name: cpqNicIfPhysAdapterSingleCollisionFrames chart_meta: description: Packets that are involved in a single collision and are subsequently transmitted successfully family: 'Network/Interface/Collision/Single' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.23 name: cpqNicIfPhysAdapterMultipleCollisionFrames chart_meta: description: Packets that are involved in multiple collisions and are subsequently transmitted successfully family: 'Network/Interface/Collision/Multiple' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.24 name: cpqNicIfPhysAdapterDeferredTransmissions chart_meta: description: Packets whose transmission was delayed on its first attempt because the medium was busy family: 'Network/Interface/Transmission/Deferred' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.25 name: cpqNicIfPhysAdapterLateCollisions chart_meta: description: A late collision is one that occurred 64 bytes or more into the packet family: 'Network/Interface/Collision/Late' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.26 name: cpqNicIfPhysAdapterExcessiveCollisions chart_meta: description: Packets that, due to excessive collisions, are not transmitted successfully family: 'Network/Interface/Collision/Excessive' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.27 name: cpqNicIfPhysAdapterInternalMacTransmitErrors chart_meta: description: Frames for which transmission on a particular interface fails due to an internal MAC sublayer transmit error family: 'Network/Interface/Error/MAC/Transmit' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.28 name: cpqNicIfPhysAdapterCarrierSenseErrors chart_meta: description: The number of times that the carrier sense signal from the physical layer interface was not asserted or was de-asserted during transmission of a packet without collision family: 'Network/Interface/Error/CarrierSense' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.29 name: cpqNicIfPhysAdapterFrameTooLongs chart_meta: description: A count of frames received on a particular interface that exceed the maximum permitted frame size family: 'Network/Interface/Error/FrameTooLong' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.30 name: cpqNicIfPhysAdapterInternalMacReceiveErrors chart_meta: description: A count of frames for which reception on a particular interface fails due to an internal MAC sublayer receive error family: 'Network/Interface/Error/MAC/Receive' unit: "{frame}/s" - OID: 1.3.6.1.4.1.232.18.2.3.1.1.33 name: cpqNicIfPhysAdapterSpeed chart_meta: description: An estimate of the interface current bandwidth family: 'Network/Interface/Speed' unit: "bit/s" metric_tags: - tag: adapter_name symbol: OID: 1.3.6.1.4.1.232.18.2.3.1.1.39 name: cpqNicIfPhysAdapterName - tag: _adapter_mac_addr symbol: OID: 1.3.6.1.4.1.232.18.2.3.1.1.4 name: cpqNicIfPhysAdapterMACAddress - MIB: CPQIDA-MIB table: OID: 1.3.6.1.4.1.232.3.2.2.1 name: cpqDaCntlrTable symbols: - OID: 1.3.6.1.4.1.232.3.2.2.1.1.6 name: cpqDaCntlrCondition chart_meta: description: Condition of the device controller family: 'Hardware/StorageController/Status' unit: "{status}" mapping: 1: other 2: ok 3: degraded 4: failed metric_tags: - tag: controller_index symbol: OID: 1.3.6.1.4.1.232.3.2.2.1.1.1 name: cpqDaCntlrIndex - tag: _controller_model symbol: OID: 1.3.6.1.4.1.232.3.2.2.1.1.2 name: cpqDaCntlrModel - tag: _controller_slot symbol: OID: 1.3.6.1.4.1.232.3.2.2.1.1.5 name: cpqDaCntlrSlot