Dir :
~
/
lib
/
netdata
/
conf.d
/
go.d
/
snmp.profiles
/
default
/
View File Name :
_std-ups-mib.yaml
metric_tags: - OID: 1.3.6.1.2.1.33.1.1.1 symbol: upsIdentManufacturer tag: ups_ident_manufacturer - OID: 1.3.6.1.2.1.33.1.1.2 symbol: upsIdentModel tag: ups_ident_model - OID: 1.3.6.1.2.1.33.1.1.5 symbol: upsIdentName tag: ups_ident_name metrics: - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.2.1.0 name: upsBatteryStatus chart_meta: family: 'Hardware/Battery/Status' description: The indication of the capacity remaining in the UPS system's batteries unit: "{status}" mapping: 1: unknown 2: batteryNormal 3: batteryLow 4: batteryDepleted - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.2.2.0 name: upsSecondsOnBattery chart_meta: family: 'System/Battery/Runtime/OnBattery' description: If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power unit: "s" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.2.3.0 name: upsEstimatedMinutesRemaining chart_meta: family: 'System/Battery/Runtime/Remaining' description: An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off unit: "min" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.2.4.0 name: upsEstimatedChargeRemaining chart_meta: family: 'System/Battery/Charge/Remaining' description: An estimate of the battery charge remaining expressed as a percent of full charge unit: "%" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.2.5.0 name: upsBatteryVoltage chart_meta: family: 'Hardware/Battery/Voltage/Value' description: The magnitude of the present battery voltage unit: "V" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.2.6.0 name: upsBatteryCurrent chart_meta: family: 'Hardware/Battery/Current/Value' description: The present battery current unit: "A" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.2.7.0 name: upsBatteryTemperature chart_meta: family: 'Hardware/Battery/Temperature/Value' description: The ambient temperature at or near the UPS Battery casing unit: "Cel" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.3.1.0 name: upsInputLineBads chart_meta: family: 'PowerFlow/Input/Error/OutOfTolerance' description: A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance unit: "{transition}" metric_type: monotonic_count - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.3.2.0 name: upsInputNumLines chart_meta: family: 'PowerFlow/Input/Line/Count' description: The number of input lines utilized in this device. This variable indicates the number of rows in the input table unit: "{line}" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.4.1.0 name: upsOutputSource chart_meta: family: 'PowerFlow/Output/Source/Status' description: The present source of output power unit: "{status}" mapping: 1: other 2: none 3: normal 4: bypass 5: battery 6: booster 7: reducer - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.4.2.0 name: upsOutputFrequency chart_meta: family: 'PowerFlow/Output/Frequency/Value' description: The present output frequency unit: "Hz" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.4.3.0 name: upsOutputNumLines chart_meta: family: 'PowerFlow/Output/Line/Count' description: The number of output lines utilized in this device. This variable indicates the number of rows in the output table unit: "{line}" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.5.1.0 name: upsBypassFrequency chart_meta: family: 'PowerFlow/Bypass/Frequency/Value' description: The present bypass frequency unit: "Hz" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.5.2.0 name: upsBypassNumLines chart_meta: family: 'PowerFlow/Bypass/Line/Count' description: The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table unit: "{line}" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.6.1.0 name: upsAlarmsPresent chart_meta: family: 'System/Alarm/Active' description: The present number of active alarm conditions unit: "{alarm}" - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.7.3.0 name: upsTestResultsSummary chart_meta: family: 'System/Test/Result/Status' description: The results of the current or last UPS diagnostics test performed unit: "{status}" mapping: 1: donePass 2: doneWarning 3: doneError 4: aborted 5: inProgress 6: noTestsInitiated - MIB: UPS-MIB symbol: OID: 1.3.6.1.2.1.33.1.7.5.0 name: upsTestStartTime chart_meta: family: 'System/Test/StartTime/Value' description: The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated unit: "s" - MIB: UPS-MIB table: OID: 1.3.6.1.2.1.33.1.4.4 name: upsOutputTable symbols: - OID: 1.3.6.1.2.1.33.1.4.4.1.2 name: upsOutputVoltage chart_meta: family: 'PowerFlow/Output/Voltage/Value' description: The present output voltage unit: "V" - OID: 1.3.6.1.2.1.33.1.4.4.1.3 name: upsOutputCurrent chart_meta: family: 'PowerFlow/Output/Current/Value' description: The present output current unit: "A" - OID: 1.3.6.1.2.1.33.1.4.4.1.4 name: upsOutputPower chart_meta: family: 'PowerFlow/Output/Power/Active' description: The present output true power unit: "W" - OID: 1.3.6.1.2.1.33.1.4.4.1.5 name: upsOutputPercentLoad chart_meta: family: 'PowerFlow/Output/Load/Usage' description: The percentage of the UPS power capacity presently being used on this output line unit: "%" metric_tags: - symbol: OID: 1.3.6.1.2.1.33.1.4.4.1.1 name: upsOutputLineIndex tag: ups_output_line_index - MIB: UPS-MIB table: OID: 1.3.6.1.2.1.33.1.3.3 name: upsInputTable symbols: - OID: 1.3.6.1.2.1.33.1.3.3.1.2 name: upsInputFrequency chart_meta: family: 'PowerFlow/Input/Frequency/Value' description: The present input frequency unit: "Hz" - OID: 1.3.6.1.2.1.33.1.3.3.1.3 name: upsInputVoltage chart_meta: family: 'PowerFlow/Input/Voltage/Value' description: The magnitude of the present input voltage unit: "V" - OID: 1.3.6.1.2.1.33.1.3.3.1.4 name: upsInputCurrent chart_meta: family: 'PowerFlow/Input/Current/Value' description: The magnitude of the present input current unit: "A" - OID: 1.3.6.1.2.1.33.1.3.3.1.5 name: upsInputTruePower chart_meta: family: 'PowerFlow/Input/Power/Active' description: The magnitude of the present input true power unit: "W" metric_tags: - symbol: OID: 1.3.6.1.2.1.33.1.3.3.1.1 name: upsInputLineIndex tag: ups_input_line_index - MIB: UPS-MIB table: OID: 1.3.6.1.2.1.33.1.5.3 name: upsBypassTable symbols: - OID: 1.3.6.1.2.1.33.1.5.3.1.2 name: upsBypassVoltage chart_meta: family: 'PowerFlow/Bypass/Voltage/Value' description: The present bypass voltage unit: "V" - OID: 1.3.6.1.2.1.33.1.5.3.1.3 name: upsBypassCurrent chart_meta: family: 'PowerFlow/Bypass/Current/Value' description: The present bypass current unit: "A" - OID: 1.3.6.1.2.1.33.1.5.3.1.4 name: upsBypassPower chart_meta: family: 'PowerFlow/Bypass/Power/Active' description: The present true power conveyed by the bypass unit: "W" metric_tags: - symbol: OID: 1.3.6.1.2.1.33.1.5.3.1.1 name: upsBypassLineIndex tag: ups_bypass_line_index - MIB: UPS-MIB table: OID: 1.3.6.1.2.1.33.1.6.2 name: upsAlarmTable symbols: - OID: 1.3.6.1.2.1.33.1.6.2.1.3 name: upsAlarmTime chart_meta: family: 'System/Alarm/Time/Value' description: The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0 unit: "s" metric_tags: - tag: ups_alarm_descr symbol: OID: 1.3.6.1.2.1.33.1.6.2.1.2 name: upsAlarmDescr