One Hat Cyber Team
Your IP :
216.73.216.42
Server IP :
203.175.9.166
Server :
Linux tanggamus.iixcp.rumahweb.net 5.14.0-427.28.1.el9_4.x86_64 #1 SMP PREEMPT_DYNAMIC Fri Aug 2 03:44:10 EDT 2024 x86_64
Server Software :
LiteSpeed
PHP Version :
7.4.33
Buat File
|
Buat Folder
Eksekusi
Dir :
~
/
lib
/
netdata
/
conf.d
/
go.d
/
snmp.profiles
/
default
/
Edit File:
avtech-roomalert-3s.yaml
extends: - avtech.yaml metadata: device: fields: type: value: "Room Alert Monitor" selector: - sysobjectid: include: - 1.3.6.1.4.1.20916.1.13.* metrics: - MIB: ROOMALERT3S-MIB symbol: OID: 1.3.6.1.4.1.20916.1.13.1.1.1.1.0 name: roomalert.3s.internal_tempf chart_meta: description: Internal temperature family: 'Hardware/Sensor/Internal/Temperature/Value' unit: "degF" - MIB: ROOMALERT3S-MIB symbol: OID: 1.3.6.1.4.1.20916.1.13.1.1.1.2.0 name: roomalert.3s.internal_tempc chart_meta: description: Internal temperature family: 'Hardware/Sensor/Internal/Temperature/Value' unit: "Cel" - MIB: ROOMALERT3S-MIB symbol: OID: 1.3.6.1.4.1.20916.1.13.1.2.1.1.0 name: roomalert.3s.digital_sen1_1 chart_meta: description: Current temperature family: 'Hardware/Sensor/Digital/Temperature/Value' unit: "Cel" - MIB: ROOMALERT3S-MIB symbol: OID: 1.3.6.1.4.1.20916.1.13.1.2.1.2.0 name: roomalert.3s.digital_sen1_2 chart_meta: description: Current temperature family: 'Hardware/Sensor/Digital/Temperature/Value' unit: "degF" # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.1.2.1.3.0 # name: roomalert.3s.digital_sen1_3 # description: If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Temp/Analog sensor, this value represents the current Voltage reading. If this is a Temp/Active Power sensor, this value represents the current power state (1=Power Detected, 0=No Power Detected). If this is a Digital Extreme Temperature sensor, this value represents the current temperature from the thermocouple in Celsius. # unit: "TBD" # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.1.2.1.4.0 # name: roomalert.3s.digital_sen1_4 # description: If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Temp/Analog sensor, this value represents the current custom reading. If this is a Digital Extreme Temperature sensor, this value represents the current temperature from the thermocouple in Fahrenheit. # unit: "TBD" # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.1.2.1.5.0 # name: roomalert.3s.digital_sen1_5 # description: If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius. If this is a Digital Extreme Temperature Sensor, this value is a fault code. 0 = no fault. # unit: "TBD" # TODO, here we don't have an OID giving us sensor type - MIB: ROOMALERT3S-MIB symbol: OID: 1.3.6.1.4.1.20916.1.13.1.2.1.6.0 name: roomalert.3s.digital_sen1_6 chart_meta: description: Current dew point family: 'Hardware/Sensor/Digital/DewPoint/Value' unit: "Cel" - MIB: ROOMALERT3S-MIB symbol: OID: 1.3.6.1.4.1.20916.1.13.1.2.1.7.0 name: roomalert.3s.digital_sen1_7 chart_meta: description: Current dew point family: 'Hardware/Sensor/Digital/DewPoint/Value' unit: "degF" - MIB: ROOMALERT3S-MIB symbol: OID: 1.3.6.1.4.1.20916.1.13.1.3.1.0 name: roomalert.3s.switch_sen1 chart_meta: description: The reading for switch sensor 1 family: 'Hardware/Sensor/Switch/Status' unit: "{status}" mapping: 0: open 1: closed # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.3.1.1.0 # name: roomalert.3s.externalrelay1_element_one # description: External relay 1 element one state # unit: "TBD" # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.3.1.2.0 # name: roomalert.3s.externalrelay1_element_two # description: External relay 1 element two state # unit: "TBD" # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.3.1.3.0 # name: roomalert.3s.externalrelay1_element_three # description: External relay 1 element three state # unit: "TBD" # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.3.1.4.0 # name: roomalert.3s.externalrelay1_element_four # description: External relay 1 element four state # unit: "TBD" # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.3.1.5.0 # name: roomalert.3s.externalrelay1_element_five # description: External relay 1 element five state # unit: "TBD" # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.3.1.6.0 # name: roomalert.3s.externalrelay1_element_six # description: External relay 1 element six state # unit: "TBD" # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.3.1.7.0 # name: roomalert.3s.externalrelay1_element_seven # description: External relay 1 element seven state # unit: "TBD" # - MIB: ROOMALERT3S-MIB # symbol: # OID: 1.3.6.1.4.1.20916.1.13.3.1.8.0 # name: roomalert.3s.externalrelay1_element_eight # description: External relay 1 element eight state # unit: "TBD" # TODO no status found
Simpan