One Hat Cyber Team
Your IP :
216.73.216.220
Server IP :
203.175.9.166
Server :
Linux tanggamus.iixcp.rumahweb.net 5.14.0-427.28.1.el9_4.x86_64 #1 SMP PREEMPT_DYNAMIC Fri Aug 2 03:44:10 EDT 2024 x86_64
Server Software :
LiteSpeed
PHP Version :
7.4.33
Buat File
|
Buat Folder
Eksekusi
Dir :
~
/
lib
/
netdata
/
conf.d
/
health.d
/
Edit File:
apcupsd.conf
# you can disable an alarm notification by setting the 'to' line to: silent template: apcupsd_ups_load_capacity on: apcupsd.ups_load_capacity_utilization class: Utilization type: Power Supply component: UPS device lookup: average -10m unaligned of load units: % every: 1m warn: $this > (($status >= $WARNING) ? (70) : (80)) delay: down 10m multiplier 1.5 max 1h summary: APC UPS load info: APC UPS average load over the last 10 minutes to: sitemgr template: apcupsd_ups_battery_charge on: apcupsd.ups_battery_charge class: Errors type: Power Supply component: UPS device lookup: average -60s unaligned of charge units: % every: 60s warn: $this < 100 crit: $this < 40 delay: down 10m multiplier 1.5 max 1h summary: APC UPS battery charge info: APC UPS average battery charge over the last minute to: sitemgr template: apcupsd_last_collected_secs on: apcupsd.ups_status class: Latency type: Power Supply component: UPS device calc: $now - $last_collected_t every: 10s units: seconds ago warn: $this > (($status >= $WARNING) ? ($update_every) : ( 5 * $update_every)) delay: down 5m multiplier 1.5 max 1h summary: APC UPS last collection info: APC UPS number of seconds since the last successful data collection to: sitemgr #Send out a warning when SELFTEST code is BT or NG. Code descriptions can be found at: #http://www.apcupsd.org/manual/#:~:text=or%20N/A.-,SELFTEST,-The%20results%20of template: apcupsd_ups_selftest_warning on: apcupsd.ups_selftest lookup: max -1s unaligned match-names of BT,NG units: status every: 10s warn: $this == 1 delay: up 0 down 15m multiplier 1.5 max 1h info: APC UPS self-test failed due to insufficient battery capacity or due to overload to: sitemgr #Send out a warning when STATUS code is ONBATT,OVERLOAD,LOWBATT,REPLACEBATT,NOBATT,COMMLOST #https://man.archlinux.org/man/apcaccess.8.en#:~:text=apcupsd%20was%20started-,STATUS,-%3A%20UPS%20status.%20One template: apcupsd_ups_status_onbatt on: apcupsd.ups_status lookup: max -1s unaligned match-names of ONBATT units: status every: 10s warn: $this == 1 delay: up 1m down 15m multiplier 1.5 max 1h info: APC UPS has switched to battery power because the input power has failed to: sitemgr template: apcupsd_ups_status_overload on: apcupsd.ups_status lookup: max -1s unaligned match-names of OVERLOAD units: status every: 10s warn: $this == 1 delay: up 0 down 15m multiplier 1.5 max 1h info: APC UPS is overloaded and cannot supply enough power to the load to: sitemgr template: apcupsd_ups_status_lowbatt on: apcupsd.ups_status lookup: max -1s unaligned match-names of LOWBATT units: status every: 10s warn: $this == 1 delay: up 0 down 15m multiplier 1.5 max 1h info: APC UPS battery is low and needs to be recharged to: sitemgr template: apcupsd_ups_status_replacebatt on: apcupsd.ups_status lookup: max -1s unaligned match-names of REPLACEBATT units: status every: 10s warn: $this == 1 delay: up 0 down 15m multiplier 1.5 max 1h info: APC UPS battery has reached the end of its lifespan and needs to be replaced to: sitemgr template: apcupsd_ups_status_nobatt on: apcupsd.ups_status lookup: max -1s unaligned match-names of NOBATT units: status every: 10s warn: $this == 1 delay: up 0 down 15m multiplier 1.5 max 1h info: APC UPS has no battery to: sitemgr template: apcupsd_ups_status_commlost on: apcupsd.ups_status lookup: max -1s unaligned match-names of COMMLOST units: status every: 10s warn: $this == 1 delay: up 0 down 15m multiplier 1.5 max 1h info: APC UPS communication link is lost to: sitemgr
Simpan